Product Name | Rapid FIV Ab/FeLV Ag Combo Test Kit |
Principle | Immunochromatographic assay |
Specimen | Whole blood, serum or plasma |
Specification | 10T/kit |
Format | Cassette |
Assay Time | 5-10 mins |
Shelf Life | 24 months |
SKU | PW0101 |
INTENDED USE
The FIV Ab/FeLV Ag Combo Rapid Test is a combined cassette to differentially diagnose the presence of Feline Immunodeficiency antibody and Feline Leukemia Virus antigen in cat’s blood specimen.
PRINCIPLE
FIV Ab + FeLV Ag Combined Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has two testing windows. Each testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough FIV antibody or FeLV antigen in the sample, a visible T band will appear in the corresponding testing window. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of FIV antibody or FeLV antigen in the sample.
KIT COMPONENT
-Test device, with disposable dropper
- Assay buffer
- Product Manual
TEST PROCEDURE
1. Collect cat’s whole blood and centrifuge it to get serum or plasma. Or use whole blood with anticoagulants as specimen. For whole blood sample without anticoagulant must be tested immediately.
2. Specimens and test kit stored at 2-8℃ should be recovered to room temperature before use.
3. Take out the test device from the foil pouch and place it horizontally.
4. Use the dropper to dispense 10ul (black line) of specimen into the sample hole “S”. Then drip 3 drops of assay buffer into the sample hold.
5. Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.
INTERPRETATION OF RESULTS
Positive: Two lines appear, no matter T line is clear or vague.
Negative: Only C line appears.
Invalid: No line appears or only T line appears.
PRECAUTIONS
1. Expired test or the test with damaged foil pouch should not be used.
2. The test must be used within 10 minutes after opening the foil pouch.
3. Do not use specimen with hemolysis or be contaminated with microbes, which will cause false positive or false negative result.
4. Do not reuse the test kit and do not mix components from different lot numbers.
5. All specimens have potential infection. It must be strictly treated according to the rules by local states.
LIMITATION
Pawiser FIV Ab/FeLV Ag Combo Rapid Test is for in vitro veterinary diagnosis use only. All results should be considered with other clinical information available from veterinarian. For an accurate result, it is suggested to apply other method such as PCR for final determination in practice.